Solvent-based cleaners come into play where aqueous cleaners are insufficient or cannot be used: parts that must not come into contact with water, lines without rinsing and drying facilities, heavy grease, resin, wax, ink and adhesive residues, and very short cycle times are the main examples.
Five criteria for choosing a solvent
| Criterion | Why it matters |
|---|---|
| Solvency | A solvent matched to the nature of the contamination dissolves it quickly. |
| Evaporation rate | Fast-evaporating solvents dry quickly without residue; slow-evaporating ones act longer on heavy soil. |
| Flash point | Determines fire safety and storage conditions. Solvents with a high flash point allow safer working. |
| Health classification | Solvents without carcinogenic, mutagenic or reproductive toxicity classification should be preferred. |
| Material compatibility | Must not cause swelling, cracking or discolouration of plastics, elastomers, paints and seals. |
Fast- and slow-evaporating solvent variants
- Fast-evaporating: Final cleaning before assembly, wiping before bonding and painting, electronic and precision parts. No waiting time needed for drying.
- Medium-evaporating: General-purpose wiping and brush cleaning.
- Slow-evaporating: Immersion, pre-soaking, dried grease and resin; low vapour loss and odour.
Non-conductive solvent forms
For maintenance cleaning of electric motors, generators, switchgear, panels and electronic boards, non-conductive solvents with high dielectric strength are used. These solvents leave no conductive residue on the surface and do not impair insulation values.
Application methods
- Wiping and brushing: Maintenance and spot cleaning.
- Spray: Fast, targeted application.
- Immersion: Batch cleaning of small parts; in covered and ventilated tanks.
- Closed / vacuum solvent machines: The most efficient and safest method in series production; the solvent is distilled and reused, minimising emissions and consumption.
Safe use
- Work in well-ventilated areas; use local exhaust ventilation in enclosed spaces.
- Keep away from flames, sparks and hot surfaces; earth equipment against static electricity.
- Wear suitable gloves and eye protection.
- Collect spent solvent in accordance with waste regulations; consider recovery options.
Frequently asked questions
Which is better, solvent or aqueous cleaner?
It depends on the application. For degreasing in series production, aqueous systems are generally more economical and safer. Solvents offer advantages for water-sensitive parts, fast drying and heavy organic residues.
Why does a film remain on the part after solvent cleaning?
Using contaminated solvent, or a slow-evaporating solvent drying on the surface, can leave a film. A final wipe with clean solvent or switching to a fast-evaporating solvent solves the problem.
Support for your solvent needs
Molkim offers fast- and slow-evaporating solvent variants without carcinogenic classification, as well as non-conductive solvent forms. If you share your application and type of contamination, we can determine the right product together.
Related products: Solvent Cleaning Products · Metal Surface Cleaning Sprays · Contact